ENGINEERING AND ENVIRONMENT TESTS

Tranduscers, data acquisition & processing

Means

Specialised technicians equip test specimens with linear or angular displacement transducers, strain gauges, pressure gauges, flow-meters, temperature, thermal flux, electrical parameters or speed measuring devices.

Features / technical details

Characteristics

Acquisition rate maximum of 2400 measurements/s. Measurements are conditioned, digitally recorded, then processed (up to 6000 channels). They are then validated and analysed by specialists.

*Means performance*

ACQUISITION & DATA PROCESSING

  • 192 strain gauge channels
  • 176 displacement transducers
  • 96 analogical channels
  • 72 thermocouple channels

PRESSURE TRANSDUCERS

  • Accuracy: 0,5 % of measuring range
  • Measurement range: from 0 to 3500 bars
  • Calibration device: from 0,4 to 1000 bars

FORCE TRANSDUCER

  • Range from 100 daN to 300 000 daN

FLOW METERS

  • Flow rate: 1,6 l/mn à 12,5 l/mn

-Accuracy: 0,5 % of measuring range

-Pressure range: 1000 bars

  • Flow rate: 83 l/mn to 1200 l/mn
  • Accuracy: 1 % of measuring range
  • Operating Pressure: 250 bars
  • Flow rate: 8,3 l/mn to 70 l/mn

-Accuracy: 0,3 % of measuring range

-Operating Pressure: 250 bars

THERMAL FLUX METERS

Fluxmeters allow the evaluation of incoming radiant thermal fluxes in a range of 10 to 10 000 kW/m²

DISPLACEMENT TRANSDUCERS

  • Resistive Transducers:

-Range: 100, 50, 25 mm

-Accuracy: 0,1 % of measuring range

  • Inductive Transducers:

-Range: 5 to 10 mm

-Accuracy: 0,5 % of measuring range

STRAIN GAUGES

  • Strain Gauges
  • Analysis Software

THERMAL SENSORS

  • Thermocouples
  • Resistive Gauges
  • Optical Pyrometers
  • Pyrometers

ACCELEROMETERS

  • Frequency Range for Calibration: 5 to 10 000 Hz
  • Range: 10 à 1000 ms-²
  • Accuracy: ± 0,7 %
  • Delivery of a calibration certificate compliant with Cofrac requirements.